Journal of Cataract & Refractive Surgery · 2003 · 255 citations · 29 references
MedicineOphthalmologySurgeryContrast SensitivityOphthalmic SurgeryRefractive SurgeryPeripheral Contrast SensitivityPostoperative Refractive OutcomesPreoperative Refractive EvaluationVisual AcuityVisual ImpairmentContrast Sensitivity ImprovementContrast Sensitivity ThresholdsControl Group DesignMatched Control GroupMonofocal Intraocular LensesSpatial Contrast Sensitivity FunctionVisual Function LossVisual Function Measurement
PURPOSE: To evaluate contrast sensitivity at distance and near after multifocal intraocular lens (IOL) implantation. SETTING: Ophthalmologic Institute of Alicante, University Miguel Hernández, Alicante, Spain. METHODS: Contrast sensitivity was measured with the Stereo Optical Functional Acuity Contrast Test at distance and near in 21 patients with a refractive multifocal IOL (Array SA-40N, AMO). A control group with a monofocal IOL (SI-40NB, AMO) was also studied to allow comparison of results. Contrast sensitivity was measured 1, 3, 6, 12, and 18 months after IOL implantation. RESULTS: There was a statistically significant greater reduction in contrast sensitivity at distance at all spatial frequencies in the multifocal group than in the monofocal group during the first month. At 3 months, contrast sensitivity at 12 and 18 cycles per deg remained reduced in the multifocal group; contrast sensitivity at the other frequencies did not differ from that in the monofocal group (P > 0.1). At 6, 12, and 18 months, contrast sensitivity at all spatial frequencies was not significantly different between groups (P > 0.1). There was a statistically significant greater reduction in near contrast sensitivity in the multifocal group than in the monofocal group at all spatial frequencies during the first and third month after surgery (P <.01). No statistically significant differences were found between groups after 6 months (P > 0.1). Contrast sensitivity at distance and near in the multifocal group improved over time (P <.01). CONCLUSIONS: The Array IOL provided contrast sensitivity at distance comparable to that obtained with the monofocal IOL between 3 and 6 months after implantation. Near contrast sensitivity improved over time but was always lower than at distance and in the monofocal near-corrected patients, which is acceptable to avoid near visual function degradation.
29
Optical performance of multifocal intraocular lenses
Jack T. Holladay, Henny van Dijk, Alan Lang et al. · Journal of Cataract & Refractive Surgery · 1990 · 212 citations