Journal of Scientific Instruments · 1962 · 14 citations · 6 references
Natural SciencesElectrical EngineeringPhysicsElectromagneticsFluid DynamicsPlasma PhysicsShock ResponseShock WavesBoundary Layer ThicknessConductivityFrequency ModulationShock DynamicsShock MeasurementShock Tube FlowShock Wave MeasurementTime Resolution
The change in inductance of a short coil due to the presence around its axis of a cylindrical, moving, electrically conducting fluid is calculated and it is shown that under certain conditions the hydromagnetic influence can be kept small. Based on these calculations, a frequency modulation circuit has been designed and calibrated which enables the measurement of conductivities of gases behind strong shocks in shock tubes to be measured with fair accuracy and adequate time resolution for the detection of local variations in flow structure. Simultaneous recording of shock streaks and conductivity oscillograms indicate that precursor signals are not detectable with this method.
6
Spectroscopic Studies of Highly Ionized Argon Produced by Shock Waves
H. E. Petschek, Peter H. Rose, H. S. Glick et al. · Journal of Applied Physics · 1955 · 106 citations
Electron Diffusion ahead of Shock Waves in Argon
Helmut D. Weymann · The Physics of Fluids · 1960 · 81 citations
The electrical conductivity of shock-ionized argon
H. J. Pain, P. R. Smy · Journal of Fluid Mechanics · 1960 · 22 citations