American Journal of Roentgenology · 1998 · 36 citations · 14 references
MedicineRadiologySurgeryDiagnostic RadiologyInterventional RadiologyVascular SurgeryDeep Vein ThrombosisIntravenous AccessIntravenous Access DevicesVascular AccessVenous AccessVenous InterventionsAdult Central Venous Access CareCentral Venous Access Device-related ExtravasationCentral Venous Access DevicesLong-term EffectivenessRadiologic ImagingVenous Access Device Assessment
OBJECTIVE: We describe our long-term experience with radiologic implantation of the Peripheral Access System (PAS) Port venous access device. Technical efficacy and complications are documented and compared with surgical and radiologic series involving other long-term venous access devices. SUBJECTS AND METHODS: Fifty-two PAS-Port catheters were implanted in 51 patients during a 30-month period. All procedures took place in the angiography suite and were performed by interventional radiologists with imaging guidance. Patients were followed up through the oncology clinic or the clinic that originally referred the patient. The durability of the catheter was evaluated, and complications were recorded during the study period. RESULTS: Fifty-two ports have been indwelling for a total of 18,357 patient-days. The mean time of implantation was 372 days, with a range of 30-825 days. Technical success in implanting the device was 100%. Device-related sepsis occurred in one patient (2%), superficial thrombophlebitis in one patient (2%), skin site dehiscence in one patient (2%), and deep vein thrombosis in one patient (2%). No instances of catheter occlusion occurred, and all catheters retained the ability to aspirate blood throughout their use. The overall complication rate was 8% (0.22/1000 patient days). CONCLUSION: Radiologic placement of this device is safe and effective. It offers many patients a superior alternative to surgically implanted chest wall ports. Complications are fewer, and chances for technical success are greater. In circumstances where cosmesis is deemed highly important, the PAS-Port device may be preferable to tunneled venous access catheters.
14
A modified right atrial catheter for access to the venous system in marrow transplant recipients.
Robert O. Hickman, CD Buckner, R. A. Clift et al. · PubMed · 1979 · 656 citations
Medicine, Cardiology, Surgery +10
Complications and management of implanted venous access catheters.
Jacob J. Lokich, Albert Bothe, Peter N. Benotti et al. · Journal of Clinical Oncology · 1985 · 282 citations
Medicine, Pharmacotherapy, Surgery +17
Quality improvement guidelines for central venous access.
PubMed · 2003 · 185 citations
Medicine, Pharmacy Practice, Surgery +14