Clinical Chemistry and Laboratory Medicine (CCLM) · 2002 · 26 citations · 18 references
MedicineGeriatric MedicineNephrologyGeriatric PharmacologyRenal PathophysiologyRenal PharmacokineticsGlomerular FiltrationRenal ClearanceRenal DiseaseRenal Function TestingRenal Function TestsRenal ImpairmentCreatinine-based BiomarkersCystatin CCystatin C-based AssessmentDiagnostic EfficiencyGlomerular Filtration Rate AssessmentGlomerular Filtration Rate MeasurementInulin ClearanceSerum Creatinine Assessment
This is a secondary analysis of data from a cross-sectional study to evaluate the diagnostic efficiency of cystatin C as a marker of the glomerular filtration rate in the elderly. Thirty patients (15 male, 15 female, mean age 75.4 +/- 7.1 years) attending a geriatric ward were enrolled. Exclusion criteria were previously diagnosed renal disease, dementia and heart failure (NYHA III or IV). Cystatin C in serum was determined by a particle-enhanced turbidimetric assay. Inulin clearance was assessed using a single-shot method. Also, Cockcroft-Gault formula was calculated. Twelve patients had a reduced glomerular filtration rate (<70 ml/min/ 1.73 m2). The mean values were 88.4 micromol/l (+/- 27.7) for serum creatinine, 1.57 mg/l (+/- 0.34) for cystatin C and 88.7 ml/min/1.73 m2 (+/- 34.6) for inulin clearance. Maximum efficiency was 0.73 for serum creatinine (cut-off limit 82 micromol/l), 0.67 for cystatin C (cut-off limit 1.63 mg/l) and 0.8 for Cockcroft and Gault estimation (cut-off limit 54 ml/min/1.73 m2). A receiver operating characteristics (ROC) analysis did not show any differences between the various methods. Therefore, cystatin C in serum may not improve the diagnostic efficiency in detecting a reduced glomerular filtration rate in the elderly. Furthermore, normal ranges for serum creatinine in the elderly might need to be adjusted.
18
Jan Kyhse‐Andersen, Camilla Wong Schmidt, Gunnar Nordin et al. · Clinical Chemistry · 1994 · 513 citations