Performance of a gas target neutron source for radiotherapy

P.M. DeLuca, R. Torti, G.M. Chenevert, Nicholas Detorie, J.R. Tesmer, Charles A. Kelsey

Physics in Medicine and Biology · 1978 · 10 citations · 7 references

Concepts

Abstract

The performance of a compact and efficient neutron generator, using the 3H(d, n) reaction and a gas target, is reported. The target is formed in a windowless, differentially pumped vessel pressurised to 7.5 Torr. An extended source of 15 MeV neutrons is produced when the target is bombarded by a 10 mA beam of 210 keV deuterons. Measurements are reported of the neutron energy spectra, neutron and gamma-ray dose rates, target lifetime and tritium handling. The neutron flux distribution of the extended target was measured and compared with the predictions of a simple beam-gas interaction model. The measured neutron source strength is 1.7 +/- 0.4 X 10(12) neutrons per second. The source output is limited by target beam current, not target power considerations.

References

7