Ozone Science and Engineering · 1989 · 12 citations · 26 references
EngineeringEnvironmental EngineeringToxicologyEnvironmental HealthWater Quality EngineeringWater TreatmentEnvironmental DisinfectionMutagenicity AssessmentChemical Mutagen SafetyChlorine ActivationDrinking Water MicrobiologyEvaluation Of Mutagenic TreatmentsMutagen Efficacy EvaluationMutagenic EffectivenessOzonation EffectsPilot Study Design
Abstract Mutagenicity produced by the oxidants chlorine, chloramines, chlorine dioxide and ozone when used in drinking water treatment was examined in a pilot scale study conducted at Edmonton, Canada. Both the Ames test, and a yeast assay using Saccharomyces cerevisiae (strain D7144–2) were employed. In the Ames test, chlorination produced utagenicity the most frequently; samples obtained following ozonation rarely were mutagenic. In the yeast assay, utagenicity was seen only infrequently. Granular activated carbon effectively removed mutagenicity for a long period of time.