Inhalation Toxicology · 2003 · 508 citations · 22 references
Public HealthPhysiologyAir PollutionPulmonologyVentilationAerosol ScienceAir PollutantsAir QualityLung DepositionParticulate MatterPulmonary PhysiologyAerosol Particle DepositionLung Deposition MeasurementParticle DepositionParticle Deposition ModelingParticulate Mass ConcentrationParticulate Matter ExposureRespiratory DepositionUltrafine Particles
Ultrafine particles (<100 nm) are believed to influence air‑pollution health effects because of their high respiratory deposition, yet measurements during spontaneous breathing are limited. The study measured fractional deposition of ultrafine carbon particles (median 26 nm) in 12 healthy adults at rest and in 7 adults during moderate exercise using a mouthpiece exposure system. Fractional deposition was high at rest (≈0.66 by number), increased with decreasing particle size, rose further during exercise (≈0.83), exceeded model predictions, and the total number of deposited particles was more than 4.5‑fold higher during exercise.
AbstractUltrafine particles (diameter < 100 nm) may be important in the health effects of air pollution, in part because of their predicted high respiratory deposition. However, there are few measurements of ultrafine particle deposition during spontaneous breathing. The fractional deposition for the total respiratory tract of ultrafine carbon particles (count median diameter = 26 nm, geometric standard deviation = 1.6) was measured in 12 healthy subjects (6 female, 6 male) at rest (minute ventilation 9.0 ± 1.3 L/min) using a mouthpiece exposure system. The mean ± SD fractional deposition was 0.66 ± 0.11 by particle number and 0.58 ± 0.13 by particle mass concentration, similar to model predictions. The number deposition fraction increased as particle size decreased, reaching 0.80 ± 0.09 for the smallest particles (midpoint count median diameter = 8.7 nm). No gender differences were observed. In an additional 7 subjects (2 female, 5 male) alternating rest with moderate exercise (minute ventilation 38.1 ± 9.5 L/min), the deposition fraction during exercise increased to 0.83 ± 0.04 and 0.76 ± 0.06 by particle number and mass concentration, respectively, and reached 0.94 ± 0.02 for the smallest particles. Experimental deposition data exceeded model predictions during exercise. The total number of deposited particles was more than 4.5-fold higher during exercise than at rest because of the combined increase in deposition fraction and minute ventilation. Fractional deposition of ultrafine particles during mouth breathing is high in healthy subjects, and increases further with exercise.
22
Human Respiratory Tract Model for Radiological Protection
Icrp · Annals of The Icrp · 1994 · 1.8K citations