Publication | Closed Access
Analysis of Protein Phosphorylation by Capillary Liquid Chromatography Coupled to Element Mass Spectrometry with <sup>31</sup>P Detection and to Electrospray Mass Spectrometry
152
Citations
8
References
2000
Year
Biological Mass SpectrometryElectrospray Mass SpectrometryBioanalysisPlasma Mass SpectrometryAnalytical ChemistryLiquid ChromatographyClinical ChemistryAnalytical BiotechnologyProteomicsElement Mass SpectrometryIsotachophoresisChromatographyIonization Mass SpectrometryCapillary ElectrophoresisBiochemistryMetabolomicsChromatographic AnalysisPharmacologyProtein PhosphorylationBiomolecular EngineeringNatural SciencesMass SpectrometryProtein Mass SpectrometryMedicineDrug Analysis
A method for phosphopeptide identification by capillary liquid chromatography (muLC) interfaced alternatively to element mass spectrometry (inductively coupled plasma mass spectrometry, ICPMS) and to electrospray ionization mass spectrometry (ESI-MS) is described. ICPMS is used for 31P detection and ESI-MS provides the corresponding molecular weight information. Alignment of the two separate muLC runs is performed using the baseline distortion at the elution front, which shows up in both muLC-ICPMS and muLC-ESI-MS. Both a quadrupole and a magnetic sector field mass analyzer were used in combination with ICP. The detection limit achieved for the muLC-ICP-HRMS runs is approximately 0.1 pmol of phosphopeptide injected. Without any further precautions, contamination by phosphate-containing compounds at this level was found to be uncritical. The method is demonstrated for the analysis of a complex mixture of synthetic phosphopeptides and a set of tryptic digests of three phosphoproteins. These include beta-casein, activated human MAP kinase ERK1, and protein kinase A catalytic subunit. The tryptic phosphopeptides of these proteins could all be detected and identified by our new strategy. Analysis of three fractions of protein kinase A catalytic subunit with different phosphorylation status gives direct access to the order in which the phosphorylation of the four phosphorylation sites occurs. The two most important aspects of using muLC-ICPMS with 31P detection for phosphopeptide identification are (i) that a high selectivity is achieved and (ii) that the signal intensity is independent of the chemical form of phosphorus and directly proportional to the molar amount of 31P in the muLC eluate. Thus, muLC-ICPMS with 31P detection is introduced as a new, robust, and specific method in phosphoproteomics.
| Year | Citations | |
|---|---|---|
1991 | 1K | |
1998 | 233 | |
1995 | 199 | |
1999 | 149 | |
1999 | 148 | |
1993 | 103 | |
1999 | 90 | |
1993 | 71 |
Page 1
Page 1