BACKGROUND: All-inside meniscal repairs are performed with increasing frequency because of the availability of newly developed devices. A comparison of their biomechanical characteristics may aid physicians in selecting a method of meniscal repair. HYPOTHESIS: All-inside meniscal repairs will be superior to their inside-out controls in response to cyclic loading and load-to-failure testing. STUDY DESIGN: Controlled laboratory study. METHODS: Sixty-six bucket-handle tears in matched porcine menisci were repaired using the Ultra FasT-Fix, Meniscal Cinch, Ultrabraid No. 0, and FiberWire 2-0 sutures. Initial displacement, cyclic loading (100, 300, and 500 cycles), and load-to-failure testing were performed. The displacement, response to cyclic loading, and mode of failure were recorded. The stiffness was calculated. RESULTS: The Meniscal Cinch demonstrated a significantly higher initial displacement than the other methods tested (P = .04). No significant difference was found among the methods in response to cyclic loading. The inside-out FiberWire repair demonstrated the highest load to failure (120.8 ± 23.5 N) and was significantly higher than both the Meniscal Cinch (64.8 ± 24.1 N, P < .001) and the Ultra FasT-Fix (88.3 ± 14.3 N, P = .002). It was not significantly higher than the inside-out Ultrabraid suture repair (98.8 ± 29.2 N). The inside-out FiberWire repair had the highest stiffness (28.7 ± 7.8 N/mm). It was significantly higher than the Meniscal Cinch (18.0 ± 8.8 N/mm, P = .01). The most common mode of failure in all methods was suture failure. CONCLUSION: An inside-out suture repair affords surgeons the best overall biomechanical characteristics of the devices tested (initial displacement, response to cyclic loading, and load to failure). For an all-inside repair, the Ultra FasT-Fix reproduces the characteristics of its matched inside-out suture repair more closely than the Meniscal Cinch. CLINICAL RELEVANCE: Inside-out sutures and all-inside devices have similar responses to cyclic loading.
22
NIH ImageJ and Slice‐O‐Matic Computed Tomography Imaging Software to Quantify Soft Tissue
Brian A. Irving, Judy Y. Weltman, David W. Brock et al. · Obesity · 2007 · 160 citations