Review of Scientific Instruments · 2006 · 14 citations · 9 references
Natural SciencesElectrical EngineeringPhysicsElectromagnetismPlasma PhysicsRadiation MeasurementElectric PotentialElectrical CharacterizationElectrical MeasurementElectron Beam PhysicsElectron TransportCoaxial ResonatorsCoaxial Transmission LinesDischarge ProcessesParallel-plate Transmission LinesSecondary Electron EmissionTest FrequenciesTransmission Line ResonatorsVacuum Systems
A multipactor discharge is a resonant condition for electrons in an alternating electric field. This discharge can be disruptive to rf circuits, cavities, and resonators. The coaxial multipactor experiment (CMX) investigates these discharges in parallel plate and coaxial transmission line geometries at frequencies from 40to150MHz with goals of measuring the electron energy distributions. CMX has a unique experimental setup that allows the transmission line to pass continuously through a short vacuum region. Retarding potential analyzers with secondary electron suppression measure the electron current as a function of bias voltage. Both parallel plate and coaxial multipactor experiments provide detailed measurements of the electron energy distributions under a variety of rf frequencies and electrode materials.
9
Handbook of chemistry and physics
Journal of the Franklin Institute · 1930 · 11.7K citations
Multipactor discharge on metals and dielectrics: Historical review and recent theories
R. A. Kishek, Y. Y. Lau, L. K. Ang et al. · Physics of Plasmas · 1998 · 346 citations · Full text
Multipacting Modes of High-Frequency Gaseous Breakdown
Albert J. Hatch, Horatio B. Williams · Physical Review · 1958 · 196 citations