Journal of Tribology · 1999 · 14 citations · 15 references
MedicineOrthopaedic SurgeryOrthopedic SurgeryBiomechanicsOrthopedic BiomechanicsOrthopedicsArthroplasty BiomechanicsHip ArthroplastyHip BiomechanicsJoint BiomechanicsJoint LubricationJoint MechanicsBiomechanical Modeling Of ProsthesesHip AnatomyHip Contact MechanicsHip Joint LoadingHip Joint MechanicsLubricationMass ConservationNumerical Flow Simulation
Formulation of a three-dimensional, quasi-static lubrication model of an artificial hip joint is proposed which includes the inclination angle of the acetabular cup. This is performed by deriving a transformed Reynolds equation accounting for this cup tilt angle. The numerical simulation also addresses mass conservation at the location of film rupture. A 3-D spherical representation of the articulating surfaces of the hip prosthesis is mapped onto a cartesian coordinate system of the entire geometry of the “ball and socket” joint. Results include the lubricating fluid pressure distributions for various inclination angles of the acetabular cup demonstrating that the greatest pressures occur for large eccentricities in the upward vertical direction.
15
Some new evidence on human joint lubrication.
A Unsworth, D. Dowson, V Wright · Annals of the Rheumatic Diseases · 1975 · 112 citations · Full text
Surface damage to cobalt-chrome femoral head prostheses
Murali Jasty, CR Bragdon, K Lee et al. · Journal of Bone and Joint Surgery - British Volume · 1994 · 85 citations · Full text