IEEE Transactions on Magnetics · 2012 · 23 citations · 13 references
EngineeringElectrical EngineeringElectromagnetismFinite Element AnalysisPower ElectronicsMagnetic CharacterizationMagnetic Circuit AnalysisMagnetic ComponentsMagnetization ProcessesNonlinear Finite Element AnalysisHarmonic Balance AnalysisHysteretic BehaviorHysteretic ModelingMagnetic Component ModelingMagnetic CoresMagnetization CurvesNonlinear Magnetic Circuit ModelingProperty Characteristics Analysis
The ferromagnetic core of power transformer is susceptible to dc bias and has special nonlinear and hysteretic characteristics under dc-biased magnetization. The dc-biasing magnetization curve of a square laminated core (SLC) can be obtained by dc bias test. The harmonic-balanced finite-element method (HBFEM) combined with the fixed-point technique is used to calculate the dc-biasing magnetic field in the SLC based on the measured dc-biasing magnetization curve. A locally convergent method in harmonic domain is presented to determine the fixed-point reluctivity, which can speed up the convergence of harmonic solution. The dc-biasing magnetic fields are computed by using the basic and dc-biasing magnetization curves respectively. The results indicate the dc-biasing magnetization curve is more reasonable than the basic one in the analysis.
13