Theoretical and experimental results on the resolving time of P.I.N. detectors in γ-γ coincidence experiments

J. Pigneret, J.J. Samueli, A. Sarazin

IEEE Transactions on Nuclear Science · 1966 · 22 citations · 2 references

Concepts

Abstract

A calculation of the resolving time one can obtain by the delayed coincidence method with a P.I.N. detector, is developed. The results show that submillimicrosecond time resolution can be obtained with a 2mm thick detector. Experimental results lead to 1.1 ns (FWHM) with a Co <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">60</sup> source and 2.8 ns with a Na <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">22</sup> source. The broadening of the prompt spectrum is explained in term of the electronic system noise.

References

2