Optimal Oral Anticoagulant Therapy in Patients with Mechanical Heart Valves

Suzanne C. Cannegieter, Frits R. Rosendaal, Axel R. Wintzen, F.J.M. van der Meer, Jan P. Vandenbroucke, E Briët

New England Journal of Medicine · 1995 · 910 citations · 19 references

DOIFull text

Open access

Abstract

The intensity of anticoagulant therapy for patients with prosthetic heart valves is optimal when the INR is between 2.5 and 4.9. To achieve this level of anticoagulation, a target INR of 3.0 to 4.0 is recommended.

References

19