Critical Care Medicine · 2000 · 18 citations · 11 references
MedicinePerioperative MedicineAnesthesiaCalcium HomeostasisSurgical InstrumentationAcid-base AssessmentElectrolyte AnalysisElectrolyte BalanceElectrolyte DisordersElectrolyte HomeostasisElectrolyte ImbalancesElectrolyte Analysis In Body FluidsElectrolyte BiomarkersPlasma Electrolyte MeasurementSerum Electrolyte MeasurementVascular PunctureWhole Blood Collection
OBJECTIVE: To compare the effects of heparin or sodium citrate used to anticoagulate indwelling arterial catheters on acid-base and electrolyte measurements. DESIGN: Randomized controlled trial. SETTING: Medical-surgical university-affiliated intensive care unit. SUBJECTS: Twenty patients with indwelling arterial catheters. INTERVENTIONS: Patients were randomly allocated to have ten 1-mL aliquots of blood sampled serially from an arterial catheter maintained with either heparin or sodium citrate. A sample then obtained by arterial puncture provided true measurement values. Acid-base and electrolyte measurements of whole blood were obtained from each sample by means of a Coming 860 analyzer. MEASUREMENTS AND MAIN RESULTS: Contamination with sodium citrate lowered ionized calcium and pH but increased glucose and Pco2. Heparin produced negligible effects on those measurements. When sodium citrate was used, reliable measurements were not obtained for ionized calcium, pH, and glucose, even after 9 mL of blood had been discarded. However, reliable P(CO2) measurements were obtained after 2 mL of blood was discarded. CONCLUSIONS: Sodium citrate used to maintain arterial catheters can contaminate blood samples. The result of that contamination can mimic severe hypocalcemia, metabolic acidosis, and mild hyperglycemia. Failure to recognize the effects of sodium citrate on acid-base and electrolyte measurements may lead to changes in treatment that could affect patient outcome adversely.
11
Arterial Embolism Occurring During Systemic Heparin Therapy
Rodger E. Weismann · Archives of Surgery · 1958 · 284 citations
Medicine, Hematology, Pharmacology +15
Too much heparin: possible source of error in blood gas analysis.
A. S. Hutchison, S H Ralston, F.J. Dryburgh et al. · BMJ · 1983 · 61 citations · Full text
Heparinized saline versus normal saline in maintaining patency of the radial artery catheter.
Makarand Kulkarni, Christian Elsner, Danièle Ouellet et al. · PubMed · 1994 · 59 citations
Medicine, Hematology, Surgery +13
Comparison of normal saline and heparin solutions for maintenance of arterial catheter patency.
G. Dennis Clifton, Pamela Branson, Hayden Kelly et al. · PubMed · 1991 · 51 citations
Medicine, Surgery, Hemostasis +6