Catheterization and Cardiovascular Diagnosis · 1995 · 11 citations · 4 references
MedicineCardiologySurgeryCardiothoracic SurgeryInterventional CardiologyVascular SurgeryAortic SurgeryBalloon AngioplastyAngioplasty Complications
We report a case of fatal aortic rupture following balloon dilation in a young female with aortoarteritis in whom restenosis of the aorta was observed 16 years after a patch aortoplasty operation. To the best of our knowledge, this complication has not been reported in aortoarteritis, although such instances have been reported in recoarctation. This unfortunate experience leads us believe that aortic segment in operated cases may be resistant to balloon dilation and vulnerable to rupture. In such cases, balloon angioplasty should either be avoided or performed with extreme caution. A sequential balloon dilation technique starting with a smaller balloon may be helpful in avoiding this complication.
4
Balloon angioplasty of the aorta in Takayasu's arteritis: Initial and long-term results
Sanjay Tyagi, U Kaul, Mohan Nair et al. · American Heart Journal · 1992 · 76 citations
Medicine, Cardiology, Surgery +8