Public HealthChemical EngineeringEnvironmental EngineeringAir PollutionAir Pollution ControlPollution ControlAir Pollutant EmissionsAir PollutantsParticulate MatterPollutant ControlSulfur DioxideSulfur OxidesBubble Column ScrubbersCollection EfficiencyRemoval EfficiencyScrubber DesignScrubber TechnologySulfur Dioxide PollutionSulfur Dioxide RemovalSulfur Dioxide Scrubbing
Abstract The emission of SO 2 from various chemical industries is associated with particulate (fly‐ash), mostly concentrations of particulate laden sulfur dioxide in and around these plants overshoot the danger point. Prediction of fly‐ash laden SO 2 removal efficiency is very important for the selection of pollution control equipment. Experimental investigations were conducted on the scrubbing of fly‐ash laden SO 2 in the modified multistage bubble column scrubber using water. Experimental results show that almost zero penetration (100% removal efficiency) of fly‐ash laden SO 2 can be achieved in this system. A correlation was developed for predicting the percentage collection efficiency of sulfur dioxide in the presence of fly‐ash. Experimental results agreed excellently with the correlation. Enhancement of SO 2 collection due to the presence of fly‐ash was also quantified.