The ID23-1 structural biology beamline at the ESRF

Didier Nurizzo, Trevor Mairs, Matias Guijarro, Vicente Rey, Jens Meyer, P. Fajardo, J. Chavanne, Jean-Claude Biasci, Seán McSweeney, Edward P. Mitchell

Journal of Synchrotron Radiation · 2006 · 162 citations · 8 references

DOIFull text

Open access

Concepts

Abstract

The demand for access to macromolecular crystallography synchrotron beam time continues to increase. To meet this demand the ESRF has constructed a dual station beamline using a canted undulator system as the X-ray source. The first phase of the beamline to be constructed is ID23-1, a tunable MAD-capable station with a mini-focus X-ray beam. The beamline makes use of well characterized optical elements: a channel-cut monochromator with a high-precision toroidal mirror to focus the X-ray beam. The beamline has been conceived with the aim of providing high levels of automation to create an industrial-like environment for protein crystallography. A new software suite has been developed to permit reliable easy operation for the beamline users and beamline staff. High levels of diagnostics are built in to allow rapid trouble-shooting. These developments are now being exported to the ESRF macromolecular crystallography beamline complex and have been made in a modular fashion to facilitate transportability to other synchrotrons.

References