American Journal of Roentgenology · 2004 · 58 citations · 27 references
MedicineCardiologyRadiologyCardiothoracic RadiologyDiagnostic ImagingDiagnostic RadiologyCardiac CatheterizationCardiac ImagingCardiovascular ImagingCoronary AngiographyCoronary Artery ImagingIntracoronary ImagingCoronary Artery Disease ImagingCoronary Lesion AssessmentCoronary Magnetic Resonance AngiographyCoronary Vascular ImagingMagnetic Resonance AngiographyQualitative Data CollectionQuantitative Coronary Angiography
OBJECTIVE: The optimal coronary MR angiography sequence has yet to be determined. We sought to quantitatively and qualitatively compare four coronary MR angiography sequences. SUBJECTS AND METHODS. Free-breathing coronary MR angiography was performed in 12 patients using four imaging sequences (turbo field-echo, fast spin-echo, balanced fast field-echo, and spiral turbo field-echo). Quantitative comparisons, including signal-to-noise ratio, contrast-to-noise ratio, vessel diameter, and vessel sharpness, were performed using a semiautomated analysis tool. Accuracy for detection of hemodynamically significant disease (> 50%) was assessed in comparison with radiographic coronary angiography. RESULTS: Signal-to-noise and contrast-to-noise ratios were markedly increased using the spiral (25.7 +/- 5.7 and 15.2 +/- 3.9) and balanced fast field-echo (23.5 +/- 11.7 and 14.4 +/- 8.1) sequences compared with the turbo field-echo (12.5 +/- 2.7 and 8.3 +/- 2.6) sequence (p < 0.05). Vessel diameter was smaller with the spiral sequence (2.6 +/- 0.5 mm) than with the other techniques (turbo field-echo, 3.0 +/- 0.5 mm, p = 0.6; balanced fast field-echo, 3.1 +/- 0.5 mm, p < 0.01; fast spin-echo, 3.1 +/- 0.5 mm, p < 0.01). Vessel sharpness was highest with the balanced fast field-echo sequence (61.6% +/- 8.5% compared with turbo field-echo, 44.0% +/- 6.6%; spiral, 44.7% +/- 6.5%; fast spin-echo, 18.4% +/- 6.7%; p < 0.001). The overall accuracies of the sequences were similar (range, 74% for turbo field-echo, 79% for spiral). Scanning time for the fast spin-echo sequences was longest (10.5 +/- 0.6 min), and for the spiral acquisitions was shortest (5.2 +/- 0.3 min). CONCLUSION: Advantages in signal-to-noise and contrast-to-noise ratios, vessel sharpness, and the qualitative results appear to favor spiral and balanced fast field-echo coronary MR angiography sequences, although subjective accuracy for the detection of coronary artery disease was similar to that of other sequences.
27
Coronary Magnetic Resonance Angiography for the Detection of Coronary Stenoses
Won Yong Kim, Peter G. Danias, Matthias Stuber et al. · New England Journal of Medicine · 2001 · 903 citations
Medicine, Cardiology, Radiology +14
Fast Spiral Coronary Artery Imaging
Craig H. Meyer, Bob S. Hu, Dwight G. Nishimura et al. · Magnetic Resonance in Medicine · 1992 · 885 citations
Medicine, Cardiology, Radiology +14