Quantitative measurement of monoclonal antibody distribution and blood flow using positron emission tomography and <sup>124</sup>iodine in patients with breast cancer
75
Citations
14
References
1991
Year
The uptake and in vivo quantitation of monoclonal antibodies (MAbs) has been measured non-invasively using positron emission tomography (PET) and 124iodine in 9 patients with breast ductal carcinoma. Blood-flow measurements were also made using 15oxygen-labelled water and PET to evaluate antibody delivery; 7 patients were studied with HMFGI antibody and 2 patients with a non-specific antibody. Tumour uptake ranged from 2-7.7 x 10(-3)% of injected dose per gram of tissue. Values for normal tissues including liver, lung and bone were also obtained. In 2 out of 7 patients studied with the specific antibody, uptake was greater than that seen with the non-specific antibody. There was no correlation between antibody uptake and blood flow. This report exemplifies the potential of PET for the non-invasive and accurate quantitative assessment of targeted antibody which is a prerequisite to therapy.