Journal of Clinical Microbiology · 2012 · 144 citations · 20 references
Life SciencesMicrobiologyBacteriologyDiagnostic MicrobiologyMedical MicrobiologyBacterial ClassificationBacterial IdentificationDiagnostic BacteriologyMass SpectrometryMicrobial IdentificationPathogen DetectionClinical Bacterial IdentificationMaldi-tof Mass SpectrometryMass Spectrometry-based IdentificationMass Spectrometry-based Microbial IdentificationMatrix-assisted Laser Desorption Ionization Time-of-flight Mass SpectrometryMatrix-assisted Laser Desorption/ionizationMatrix-assisted Laser Desorption/ionization Time-of-flight Mass SpectrometryPhenotypic Bacterial Identification
Rapid and cost-effective matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS)-based systems will replace conventional phenotypic methods for routine identification of bacteria. We report here the first evaluation of the new MALDI-TOF MS-based Vitek MS system in a large clinical microbiology laboratory. This system uses an original spectrum classifier algorithm and a specific database designed for the identification of clinically relevant species. We have tested 767 routine clinical isolates representative of 50 genera and 124 species. Vitek MS-based identifications were performed by means of a single deposit on a MALDI disposable target without any prior extraction step and compared with reference identifications obtained mainly with the VITEK2 phenotypic system; if the identifications were discordant, molecular techniques provided reference identifications. The Vitek MS system provided 96.2% correct identifications to the species level (86.7%), to the genus level (8.2%), or within a range of species belonging to different genera (1.3%). Conversely, 1.3% of isolates were misidentified and 2.5% were unidentified, partly because the species was not included in the database; a second deposit provided a successful identification for 0.8% of isolates unidentified with the first deposit. The Vitek MS system is a simple, convenient, and accurate method for routine bacterial identification with a single deposit, considering the high bacterial diversity studied and as evidenced by the low prevalence of species without correct identification. In addition to a second deposit in uncommon cases, expanding the spectral database is expected to further enhance performances.
20
Piseth Seng, Michel Drancourt, Frédérique Gouriet et al. · Clinical Infectious Diseases · 2009 · 1.9K citations
Suzanne Q. van Veen, Eric C. J. Claas, Ed J. Kuijper · Journal of Clinical Microbiology · 2010 · 656 citations · Full text
Alain Bizzini, Christian Durussel, Jacques Billé et al. · Journal of Clinical Microbiology · 2010 · 600 citations · Full text
Abdessalam Cherkaoui, Jonathan R. Hibbs, Stéphane Emonet et al. · Journal of Clinical Microbiology · 2010 · 522 citations · Full text