Natural SciencesNuclear EngineeringPhysicsNuclear PhysicsOpticsParticle PhysicsAccelerator PhysicsCollider PhysicsElectron Beam PhysicsLaser PhysicsLaser-plasma InteractionsParticle DetectorsBeam InstrumentationBeam Path GeometryBeam Position MonitoringBeam ProfilingCompton Scattering DetectionElectron-positron CollisionsHigh-intensity Beam PhysicsLaser Pulse Duration
Beam size estimates made using beam-beam deflections are used for optimization of the Stanford Linear Collider (SLC) electron-positron beam sizes. Typical beam sizes and intensities expected for 1996 operations are 2.1 × 0.6 μm (x, y) at 4.0 × 1010 particles per pulse. Conventional profile monitors, such as scanning wires, fail at charge densities well below this. The laser-based profile monitor uses a finely-focused 350-nm wavelength tripled YLF laser pulse that traverses the particle beam path about 29 cm away from the e+/e− IP. Compton scattered photons and degraded e+/e− are detected as the beam is steered across the laser pulse. The laser pulse has a transverse size of 380 nm and a Rayleigh range of about 5 μm.