Energy & Fuels · 1999 · 61 citations · 32 references
Natural SciencesChemistryAnalytical ChemistryChromatographic AnalysisMass Spectrometric AnalysisAnalytical ChromatographyChromatographic Data AnalysisChromatographyInstrumental AnalysisMass SpectrometrySize-exclusion ChromatographyAnalytical Size-exclusion ChromatographyAromatic HydrocarbonsExtra PeaksOrganic Compound AnalysisPolycyclic Aromatic Hydrocarbon AnalysisPolycyclic Aromatic HydrocarbonsSize-exclusion Liquid ChromatographyStandard Reference Materials
This paper describes the elution behavior of model compounds in a polystyrene−divinylbenzene SEC column with NMP as mobile phase, operating at high temperature (80 °C). Model compounds covering polycyclic aromatic hydrocarbons, azaarenes, and other nitrogen and polar compounds have been studied. Most of the standard compounds eluted within one minute of the expected time indicated by the polystyrene calibration. The fractionation of a complex coal-derived sample (a coal tar pitch) using the same column has been achieved, with subsequent reinjection and analysis of the fractions by heated-probe mass spectrometry and UV-fluorescence. The probe-MS experiments were performed in order to show that the material of the excluded peak does not consist of small and polar molecular species, rather than larger-molecular mass material. All the fractions were reinjected and some of them gave small extra peaks in the SEC chromatogram. The earliest fractions showed very weak UV-fluorescence indicating the presence of very high molecular mass material. The later-eluting fractions showed relatively strong fluorescence intensities with the position of the fluorescence intensities shifting to shorter wavelengths as the SEC elution time increased, indicating that the smaller polynuclear aromatic ring systems elute in the late fractions. Probe mass spectra showed that only those fractions isolated from SEC at the long elution times gave signals characteristic of aromatic and nitrogen compounds; the molecular mass range decreased with increasing elution time. Since the structures of the material excluded from the column or even that near the exclusion limit are not known, it is impossible to select standard materials or standard polymeric compounds to represent the molecular mass range of coal-derived liquids. For this reason, we believe that the polystyrene calibration represents the most reasonable compromise for SEC in NMP solvent in our system.
32
UV-Fluorescence Spectroscopy of Coal Pyrolysis Tars
Chun‐Zhu Li, Fan Wu, Haiyong Cai et al. · Energy & Fuels · 1994 · 126 citations
Molecular mass calibration in size-exclusion chromatography of coal derivatives
Keith D. Bartle, Michael J. Mulligan, N.J. Taylor et al. · Fuel · 1984 · 87 citations
Alan A. Herod, Shengfu Zhang, Barry R. Johnson et al. · Energy & Fuels · 1996 · 86 citations