Transactions of the ASAE · 1994 · 30 citations · 0 references
EngineeringArchitectural EngineeringAerodynamicsThermal ComfortVentilationAirflow DistributionBuilding AerodynamicsExperimental AerodynamicsExternal AerodynamicsVentilation Performance EvaluationVentilation SystemsBuilding Envelope AerodynamicsFlow Pattern AnalysisInlet AerodynamicsInlet DesignMomentum TheoryMomentum TransferReynolds NumberReynolds Number Effects
As measures of air flow pattern similarity in Slotted-Inlet Ventilated Enclosures (SIVE), the inlet Reynolds number (Re) and the inlet jet momentum number (J) were found to be inappropriate. A criterion was derived from the ratio of inlet jet momentum to the momentum loss due to shear along the inside walls and was denoted as inlet jet momentum ratio (RM). Appropriateness of the criterion was shown analytically and was confirmed experimentally. Further investigations of the momentum ratio and near-floor air velocity relationship, and its relation to animal comfort, is recommended.