Journal of Pediatric Orthopaedics · 1990 · 84 citations · 0 references
MedicineOrthopaedic SurgeryOrthopedic SurgeryOrthopedicsSpinal BiomechanicsSpine SurgeryNeuromuscular ScoliosisPediatric ScoliosisPediatric Spine SurgerySpinal AlignmentSpinal AnatomySpinal InstrumentationPediatric Scoliosis SurgeryPosterior ApproachPostoperative Complications In ScoliosisSagittal Plane DeformitySpinal Deformity CorrectionSpinal Deformity ManagementSurgical Alignment CorrectionSurgical Wound Dehiscence
Ten patients with neuromuscular scoliosis and pelvic obliquity had segmental spinal instrumentation using a unit Luque rod with sublaminar wires and fixation into the pelvis. Nine of the 10 patients also had anterior spinal fusion without instrumentation before the posterior procedure. Average preoperative pelvic obliquity was 42 degrees which was corrected to 6 degrees (82% correction). Average preoperative scoliosis was 92 degrees, which was corrected to 16 degrees (81% correction). Complications included a wound hematoma in one patient and a superficial wound dehiscence in another. There have been no pseudarthroses or hardware failures to date. Excellent correction of the pelvic obliquity and the spinal curve in neuromuscular scoliosis can be obtained with use of a unit rod and without use of anterior instrumentation.