Key engineering materials · 2013 · 10 citations · 4 references
EngineeringThermographyTemperature SensorMeasurementCalibrationMechanical EngineeringTemperature MeasurementEducationHot WorkingThermal AnalysisRoll BiteThermal ModelingThermodynamicsHeat TransferInstrumentationThermal SensorThermal EngineeringInverse Calculation
A temperature sensor with a thermocouple placed at ~0.5 mm from roll surface is used in hot rolling conditions to evaluate by inverse calculation heat transfers in the roll bite. Simulation analysis in industrial hot rolling conditions with short contact lengths (e.g. short contact times) and high rolling speeds (7 m./sec.) show that the temperature sensor + inverse analysis with a high acquisition frequency (> 1000 Hz) is capable to predict with a good accuracy (5 to 10% error) the roll bite peak of temperature as well as the roll surface temperature evolution all around the roll rotation. However as heat flux is more sensitive to noise measurement, the peak of heat flux in the bite is strongly under-estimated (40% error) by the inverse calculation and thus only an average roll bite heat flux could be expected from the sensor (these simulation results will be verified with an industrial trial that is being prepared). Rolling tests on a pilot mill with low rolling speeds (from 0.3 to 1.5 m./sec.) and strip reductions varying from 10 to 40% have been performed with the temperature sensor. Analysis of the tests by inverse calculation show that at low speed (<0.5 m="" sec="" and="" large="" contact="" lengths="" reduction:="" 30="" to="" 40="" the="" roll="" bite="" peak="" of="" heat="" flux="" reconstructed="" by="" inverse="" calculation="" is="" correct="" at="" higher="" speeds="" 1="" 5="" smaller="" reduction="" :="" 10-20="" reconstruction="" incorrect:="" in="" under-estimated="" though="" its="" average="" value="" analysis="" reveals="" also="" that="" transfer="" coefficient="" htc="" sub="">roll-bite (characterizing heat transfers between roll and strip in the bite) is not uniform along the roll bite but is proportional to the local rolling pressure. Finally, based on the above results, simulations with a roll thermal fatigue degradation model in industrial hot rolling conditions show that the non uniform roll bite Heat Transfer Coefficient HTC roll-bite may have in certain rolling conditions a stronger influence on roll thermal fatigue degradation than the equivalent (e.g. same average) HTC roll-bite taken uniform along the bite. Consequently, to be realistic the roll thermal fatigue degradation model has to incorporate this non uniform HTC roll-bite .
4
Nicolas Legrand, Nathalie Labbe, Daniel Weisz-Patrault et al. · Key engineering materials · 2012 · 16 citations · Full text
Electrical Engineering, Heat Transfer Process, Engineering +15
Experimental study of heat transfer in hot rolling
Petr Kotrbáček, Miroslav Raudenský, J. Horský et al. · Revue de Métallurgie · 2006 · 14 citations
Daniel Weisz-Patrault, Alain Ehrlacher, Nicolas Legrand et al. · Advanced materials research · 2012 · 10 citations · Full text
Interfacial Heat Flux, Engineering, Mechanical Engineering +17