Annals of Surgery · 2002 · 109 citations · 33 references
The omentum can be safely harvested and reliably used to reconstruct a diverse range of extraperitoneal wounds and defects. Donor-site complications can be significant but are usually limited to abdominal wall infection and hernia. Risk factors associated with complications include the use of pedicled flaps, mediastinitis, and pulmonary failure. This low rate of donor-site complications strongly supports the use of the omentum in the reconstruction of complex wounds and defects.
33
M. J. Jurkiewicz, Phillip G. Arnold · Annals of Surgery · 1977 · 190 citations · Full text
Surgical Oncology, Brachytherapy, Reconstructive Surgery +14
[The use of the great omentum in the surgery of breast cancer].