Journal of Physics D Applied Physics · 1998 · 979 citations · 4 references
Natural SciencesMaterials EngineeringMaterials ScienceAnalytical ChemistryChemical KineticsThermodynamicsChemical Kinetics ModelingChemical Reaction KineticsKinetic ModelingLuminescent MaterialsActivation EnergyActivation Energy DeterminationGlow CurvesSecond-order Kinetics
Thermoluminescence glow-curve deconvolution (GCD) functions are proposed for first, second and general orders of kinetics. The free parameters of the GCD functions are the maximum peak intensity and the maximum peak temperature , which can be obtained experimentally. The activation energy (E) and the order of kinetics (b) in the case of general order kinetics are the additional free parameters.
4
Effects of Various Heating Rates on Glow Curves
R. Chen, S. A. A. Winer · Journal of Applied Physics · 1970 · 292 citations