Poor adherence to neonatal resuscitation guidelines exposed; an observational study using camera surveillance at a tertiary hospital in Nepal

59

Citations

9

References

2014

Year

Abstract

CCD camera technique was a feasible method to assess resuscitation practices in this low resource hospital setting. In most aspects, the staff did not adhere to guidelines regarding neonatal resuscitation. The use of bag-and-mask ventilation was inadequate, and suction was given excessively in terms of protocol. Further studies exploring the underlying causes behind the lack of adherence to the neonatal resuscitation guidelines should be conducted.