The American Journal of Gastroenterology · 2003 · 528 citations · 14 references
MedicineClinical SciencesBioinstrumentationGastroenterologyPatient SafetyAcid-base AssessmentEsophageal DiseasesGastroesophageal Reflux DiseaseTelehealth SystemsTelemedicine24-Hour Ph MonitoringAmbulatory Ph MonitoringOnline Ph MonitoringPh Measurement In Body FluidsPh MonitoringRecordingsSquamocolumnar JunctionSubjects
OBJECTIVE: Limitations of catheter-based esophageal pH monitoring are discomfort, inconvenience, and interference with normal activity. An alternative to conventional pH monitoring is the wireless Medtronic Bravo pH System. The aim of this study was to evaluate the safety, performance, and tolerability of this system. METHODS: A total of 44 healthy subjects and 41 patients with gastroesophageal reflux disease (GERD) were studied for a 2-day period. The pH telemetry capsule was positioned transorally 6 cm above the squamocolumnar junction using endoscopic measurement. The signal transmitted from the capsule was received and recorded by a small, pager-sized receiver, and pH data were subsequently uploaded to a computer for analysis. RESULTS: Successful 24-h pH studies were completed in 82 subjects (96%). During the 24-h study period the median percentage of the time that pH was <4 was 2.3% (95th percentile, 5.9%) in controls and 6.5% (range, 0.8-27.6) in GERD patients. In 76 subjects (89%), 36-48 h recordings were obtained. For the extended period the median percentage of the time that pH was <40 was 2.0% (95% percentile, 5.3%) in controls and 6.6% (range, 1.0-26.7) in GERD patients. Capsules required endoscopic removal in three subjects (4%). Optimal sensitivity in distinguishing controls from reflux patients was achieved when analyzed from the perspective of the worst of the 2 days. CONCLUSIONS: The wireless Bravo pH System successfully recorded esophageal acid exposure in 96% of the patients during a 24-h period and in 89% of subjects for >36 h. The 95th percentile for the 2-day recordings in control subjects was 5.3%, slightly higher than observed with conventional systems.
14
Ambulatory 24-hour esophageal pH monitoring
Gregory Wiener, Timothy M. Morgan, J. B. Copper et al. · Digestive Diseases and Sciences · 1988 · 326 citations
Normal 24-Hr ambulatory esophageal pH values
Joel E. Richter, Laurence A. Bradley, Tom R. DeMeester et al. · Digestive Diseases and Sciences · 1992 · 317 citations
The effect of hiatus hernia on gastro-oesophageal junction pressure
Peter J. Kahrilas, Shezhang Lin, Jiakuo Chen et al. · Gut · 1999 · 316 citations · Full text
Reflux related symptoms in patients with normal oesophageal exposure to acid.
G.Y. Shi, Stanislas Bruley des Varannes, Carmelo Scarpignato et al. · Gut · 1995 · 252 citations · Full text