American Journal of Roentgenology · 2005 · 21 citations · 26 references
MedicineNuclear MedicineRadiologyDiagnostic ImagingDiagnostic Nuclear MedicineDiagnostic RadiologyCardiac ImagingCardiovascular ImagingCoronary Artery ImagingMagnetic Resonance ImagingMyocardial Perfusion ImagingPerfusion ImagingCardiac Myocardial Perfusion ImagingCoronary Artery Disease DetectionCoronary Artery Disease ImagingDelayed Enhancement ImagingMyocardial Perfusion ReserveMyocardial Perfusion ScintigraphyQuantitative Myocardial Perfusion ImagingRest Myocardial Perfusion Imaging
OBJECTIVE: Providing high temporal and spatial resolution, perfusion MRI is an attractive alternative to traditional radionuclide methods like SPECT and PET. Although first-pass perfusion MRI examinations have gained increasing attention during the past years, this technique still exhibits relatively low signal-to-noise ratio and cardiac coverage. Previous studies have suggested that refocused gradient sequence technology (e.g., true fast imaging with steady-state precession [FISP]) should improve perfusion MRI examinations. The aim of this study was to assess myocardial perfusion deficits in patients with proven coronary artery disease using a saturation recovery true FISP perfusion sequence. SUBJECTS AND METHODS: Rest and stress perfusion MRI studies were performed in 22 patients with coronary artery disease at 1.5 T using a multislice saturation recovery true FISP sequence after the bolus injection of 0.025 mmol/kg of body weight of gadopentetate dimeglumine. The myocardium of each slice was divided into 12 radial segments with subdivision into subendocardial and subepicardial subregions. Myocardial perfusion was assessed semiquantitatively and independently for each subregion. The standard of reference for myocardial perfusion was SPECT. Delayed enhancement images were acquired after the injection of 0.15 mmol/kg of body weight of gadopentetate dimeglumine. RESULTS: Sensitivity and specificity of perfusion MRI examinations for the detection of perfusion deficits were 81% and 89%, respectively, for the semiquantitative perfusion parameter upslope and 78% and 86% for the parameter peak signal intensity. More specifically, rest perfusion examinations were able to detect areas of infarction, whereas stress examinations increased the perfusion differences between normal and ischemic myocardial areas. Excellent correlation was observed between rest perfusion and late enhancement findings (r = 0.90). CONCLUSION: In patients with single-vessel coronary artery disease, perfusion deficits can reliably be detected using a saturation recovery true FISP sequence. Semiquantitative perfusion parameters upslope and peak signal intensity yielded similar results.
26
Assessment of Myocardial Perfusion in Coronary Artery Disease by Magnetic Resonance
Juerg Schwitter, Daniel Nanz, Stefan Kneifel et al. · Circulation · 2001 · 662 citations · Full text
Magnetic Resonance Perfusion Measurements for the Noninvasive Detection of Coronary Artery Disease
Eike Nagel, Christoph Klein, Ingo Paetsch et al. · Circulation · 2003 · 624 citations · Full text
Medicine, Cardiology, Radiology +17
Myocardial perfusion reserve: assessment with multisection, quantitative, first-pass MR imaging.
Norbert Wilke, Michael Jerosch‐Herold, Yang Wang et al. · Radiology · 1997 · 388 citations
Medicine, Cardiology, Radiology +17