Health Physics · 1991 · 42 citations · 0 references
EngineeringEnvironmental EngineeringEnvironmental SciencesEnvironmental MonitoringNuclear InstrumentationRadiation MeasurementAir Pollution MeasurementAir QualityAmbient Air QualityBackground Radiation MeasurementEnvironmental InstrumentationIndoor Air PollutionDetector Response UncertaintyIndoor Air Quality MeasurementIndoor Air SamplingIndoor Contaminant MonitoringIndoor Environmental MonitoringIndoor Pollution AssessmentMonitorsResidential Exposure Measurement
Annual average indoor 222Rn concentrations in 40 residences in and around Grand Junction, CO, have been measured repeatedly since 1984 using commercial alpha-track monitors (ATM) deployed for successive 12-mo time periods. Data obtained provide a quantitative measure of the year-to-year variations in the annual average Rn concentrations in these structures over this 6-y period. A mean coefficient of variation of 25% was observed for the year-to-year variability of the measurements at 25 sampling stations for which complete data were available. Individual coefficients of variation at the various stations ranged from a low of 7.7% to a high of 51%. The observed mean coefficient of variation includes contributions due to the variability in detector response as well as the true year-to-year variation in the annual average Rn concentrations. Factoring out the contributions from the measured variability in the response of the detectors used, the actual year-to-year variability of the annual average Rn concentrations was approximately 22%.