Materialwissenschaft und Werkstofftechnik · 2007 · 36 citations · 32 references
MedicineOrthopaedic SurgeryOrthopedic SurgeryImplant SurgeryOrthopaedic BiomaterialsOrthopedic BiomaterialsBone BiomechanicsBone MechanicsImplant BiomechanicsImplant DesignImplant MaterialsImplant Prosthesis DesignBeta Titanium AlloysProsthesis DesignTitanium AlloysTitanium BiocompatibilityTitanium Implant MaterialsTitanium MaterialsTotal Hip Arthroplasty BiomechanicsYoung's Modulus
Abstract Titanium alloys ‐ type (α+β) ‐ like Ti6Al7Nb or Ti6Al4V are widely used in cementless total hip arthroplasty due to their lower modulus, biocompatibility and enhanced corrosion resistance in comparison to Stainless Steel or Cobalt‐Chromium implant materials. Several articles report about atrophy of the proximal femur in cases where long stems with a big diameter made of (α+β) Titanium alloys with a relatively high value of the Youngs’ Modulus (110 GPa) in comparison to the Youngs’ Modulus of cortical bone (15–25 GPa) have been implanted using a prosthesis design with distal anchorage technique. Meanwhile several implant manufacturers have developed a new group of biocompatible Beta‐Titanium alloys with a lower Youngs’ Modulus around 70 GPa. This article gives an overview of the current status of available low modulus Titanium alloys including their mechanical characteristics and future developments.
32
R. Huiskes, Harrie Weinans, Bert van Rietbergen · Clinical Orthopaedics and Related Research · 1992 · 1.2K citations · Full text
Structure and properties of cast binary Ti–Mo alloys
Wen-Fu Ho, C.P. Ju, J.H. Chern Lin · Biomaterials · 1999 · 675 citations
Natural Sciences, Materials Engineering, Materials Science +10