Journal of Endovascular Surgery · 1995 · 32 citations · 11 references
MedicineSurgeryAutopsy PathologyCardiothoracic SurgeryVascular SurgeryAneurysm RepairAneurysm SurgeryAortic Aneurysm RepairAortic DiseaseAortic SurgeryEndovascular SurgeryAneurysm Sac ExclusionAortic Graft ReplacementClinical AutopsyComplications Of Aneurysm RepairEndovascular Aortic Aneurysm RepairEndovascular ReconstructionInfrarenal Aneurysm RepairRuptured Aortic Aneurysm Repair
PURPOSE: To report the results of a postmortem examination in a patient who died of unrelated causes 7 months following endoluminal treatment of an infrarenal abdominal aortic aneurysm (AAA). METHODS: As part of an FDA Phase I pilot study, a 73-year-old man underwent successful endoluminal exclusion of an infrarenal AAA using a 9-cm-long endograft (Endovascular Grafting System). Seven months later, he succumbed to complications of a spontaneous esophageal rupture. At autopsy, the aorta was dissected in situ by a vascular surgeon and pathologist before being explanted in order to examine the wound healing characteristics at the aorta-endograft interface. Particular attention was also directed to the hooks composing the attachment system at each end of the endograft. RESULTS: Macroscopic and microscopic examination revealed that the graft had completely excluded the aneurysm sac from the circulation and was incorporated into the aortic wall at the proximal neck and distal cuff. A smooth pannus of endothelial cells covered the proximal end of the endograft at the areas of contact with the aorta, while microscopic examination of the distal end of the graft revealed poorly formed, fibrinous pannus. The neointima deep to the endothelium consisted of a collagenous matrix containing myofibroblasts and histiocytes, providing evidence of healing between the endograft and aorta. Both renal arteries were clear of the proximal end of the endograft, but a previously unrecognized right lower pole renal artery with an extremely caudal origin was excluded from the aortic lumen. Each hook of the attachment system was seen protruding through the adventitia of the aorta. There was no evidence of trauma to the aortic wall or the surrounding tissues caused by these hooks. CONCLUSION: There appears to be evidence that an endoluminally placed aortic graft may be incorporated by the host aortic tissue.
11
Healing of Arterial Prostheses in Man
K Berger, Lester R. Sauvage, Alloju M. Rao et al. · Annals of Surgery · 1972 · 448 citations · Full text
Medicine, Cardiology, Surgery +5
Transluminal expandable nitinol coil stent grafting: preliminary report.
Dotter Ct, R W Buschmann, M McKinney et al. · Radiology · 1983 · 326 citations