A Hybrid Reinforced Precast Frame for Seismic Regions

John F. Stanton, William C. Stone, Geraldine S. Cheok

PCI Journal · 1997 · 249 citations · 6 references

Concepts

Abstract

A precast, prestressed concrete framing system for resisting earthquake loads is described. The system uses both unbonded post-tensioned reinforcement and bonded bar reinforcement. Tests have shown that its performance is equal or superior to that of a conventional cast-in-place moment frame. Design criteria and code implications resulting from the test program as well as suggested topics for future research are discussed.

References

6