Comparison of Magnetic Resonance Imaging Sequences With Computed Tomography to Detect Low-Grade Subarachnoid Hemorrhage

Ant nio Jos da Rocha, Carlos Jorge da Silva, Hugo Pereira Pinto Gama, Carlos E. Baccin, Fl vio T lio Braga, Fabiane de Ara jo Cesare, Jos Carlos Esteves Veiga

Journal of Computer Assisted Tomography · 2006 · 67 citations · 45 references

Concepts

Abstract

OBJECTIVES: To compare computed tomography (CT) with magnetic resonance imaging (MRI) for the presumptive diagnosis and localization of acute and subacute low-grade subarachnoid hemorrhage (SAH). METHODS: We consecutively enrolled 45 patients clinically suspected of low-grade SAH, comparing them with a control group. We obtained axial nonenhanced CT scans as well as fluid-attenuated inversion recovery (FLAIR) and T2-weighted gradient echo (T2*) MRI sequences at 1.0 T. Two neuroradiologists scrutinized the presence of blood at 26 different regions in the intracranial subarachnoid space (SAS). RESULTS: Three of 45 patients had normal CT and MRI scans, and SAH was excluded by lumbar puncture. We demonstrated SAH on CT scans in 28 of 42 (66.6%) patients, T2* sequences in 15 of 42 (35.7%) patients, and FLAIR sequences in 42 of 42 (100%) patients. Fluid-attenuated inversion recovery sequences were superior to CT in 16 of the 26 evaluated regions. CONCLUSIONS: The FLAIR sequence was superior for presumptive diagnosis and localization of acute and subacute low-grade SAH, representing a potential tool in this setting.

References

45