Limnology and Oceanography Methods · 2014 · 47 citations · 26 references
EngineeringEnvironmental SciencesOceanographyEnvironmental MonitoringOptoelectronicsSensorsEnvironmental SensingMarine SensorsOptical Ocean SensorsOptical SensingOptical SensorsPressure MeasurementAccuracyCarbon DioxideCarbon Dioxide DetectionCarbon Dioxide MonitoringCarbon Dioxide SensingDissolved Carbon Dioxide MeasurementDissolved Gas MeasurementDynamic Range
This article reports the performance of an improved, newly developed, compact, low power, lifetime‐based optical sensor (optode) for measuring partial pressure of dissolved CO 2 gas (pCO 2 ) in natural waters. The results suggest that after preconditioning, these sensors are stable in water for time periods longer than 7 months. The wide dynamic range of about 0‐50000 µatm opens possibilities for numerous applications of which some are presented. In normal marine environments with pCO 2 levels of 200‐1000 µatm, the best‐obtained precision was about ±2 µatm, and the absolute accuracy was between 2‐75 µatm, depending on the deployment and the quality of the collected reference water samples. One limitation is that these sensors will become irreversibly poisoned by H 2 S and should thus not be deployed in sulphidic environments.
26
Carbon dioxide in water and seawater: the solubility of a non-ideal gas
Ray F. Weiss · Marine Chemistry · 1974 · 3.5K citations
Taro Takahashi, Stewart C Sutherland, Rik Wanninkhof et al. · HAL (Le Centre pour la Communication Scientifique Directe) · 2009 · 2.5K citations
Enhanced Open Ocean Storage of CO <sub>2</sub> from Shelf Sea Pumping
Helmuth Thomas, Yann Bozec, Khalid Elkalay et al. · Science · 2004 · 544 citations · Full text