The DVF spatial accuracy required to meet a dose mapping accuracy tolerance depends on the spatial location within the dose distribution. For dose mapping, DVFs accuracy must be highest in dose gradient regions, while less accurate DVFs can be tolerated in uniform dose regions. The DTD tool provides a useful first estimate of DVF required spatial accuracy.