Ozonation for the Degradation of Organic Compounds from Nuclear Laundry Water

Miia Vilve, Teemu Törönen, Mika Sillanpää

Ozone Science and Engineering · 2008 · 12 citations · 11 references

Concepts

Abstract

Abstract In this study, the efficiency of ozone to degrade organic compounds of nuclear laundry water was studied at different pH and temperatures and at elevated temperature with hydrogen peroxide. The degradation of non-ionic surfactant and other organic compounds was analyzed by COD, TOC, BOD and molecular weight distribution measurements. Zeta potential measurements were also performed in order to interpret the obtained results. The most favorable degradation conditions were at pH 7 with 43%, 34% and 61% reductions of COD, TOC and BOD, respectively. Keywords: OzoneNon-Ionic SurfactantNuclear Laundry WaterpHTemperature ACKNOWLEDGMENTS The financial support from EU, city of Mikkeli and Platom Oy is gratefully acknowledged. The authors of this paper are also thankful to Markus Tauriainen for his technical support and to Nanna Karlsson for her contribution to the laboratory experiments.

References

11