Mutual Effect of Current Density, pH, Temperature, and Hydrodynamic Factors on Current Efficiency in the Chlorate Cell Process

Milan M. Jakšić

Journal of The Electrochemical Society · 1974 · 29 citations · 0 references

Concepts

Abstract

The simultaneous mutual effect of pH, temperature, current density, and hydrodynamic factors on current efficiency in the chlorate cell process has been investigated and considered. Certain practical considerations of the process optimization are also given. Some contributions to the scale‐up of chlorate cells have also been introduced. It has been pointed out that by adjusting all other parameters at their optimal values (temperature, pH, and the linear velocity of flow), the current density is then the main factor providing high current yields.