Transfusion · 2008 · 51 citations · 11 references
MedicineHematologyInternal MedicineGood Clinical PracticePatient SafetyTransfusion MedicineBlood Transfusion ManagementBlood Transfusion SafetyCryoprecipitate TherapyCryoprecipitate TransfusionTransfusion SupportTransfusion TherapyAllogeneic TransfusionCryoprecipitate EfficacyCryoprecipitate Utilization ReviewFibrinogen ConcentratesFibrinogen Concentration MonitoringGuidelines For Cryoprecipitate UseMedical IndicationTransfusion Indications
BACKGROUND: Canadian Blood Services' disposition reports suggested considerable variation in cryoprecipitate use and prompted this national audit. STUDY DESIGN AND METHODS: Thirty-one institutions were invited to participate in a 2-month audit. Patient information and relevant laboratory and transfusion data were collected. Cryoprecipitate transfusions were categorized as appropriate if a fibrinogen level (taken 6 hr before/after transfusion) was not more than 1.0 g per L and inappropriate if the pretransfusion fibrinogen level was more than 1.0 g per L and posttransfusion fibrinogen level was more than 1.0 g per L or not performed. Appropriateness was categorized as undetermined if the pretransfusion fibrinogen level was not performed and the posttransfusion fibrinogen level was more than 1.0 g per L or not performed. RESULTS: Overall, 25 of 31 invited hospitals agreed to participate. A total of 4370 units of cryoprecipitate were transfused in 603 events to 453 patients representing 62 percent of cryoprecipitate issued to hospitals during the time period. Comparison of the number of units of cryoprecipitate per 100 units of red blood cells (RBCs) transfused by each institution showed significant variation in practice (mean, 9 per 100 RBCs; range, 2 to 27 units). The single most common indication for cryoprecipitate was cardiac surgery (45.4% of events). Overall, 24 percent of cryoprecipitate transfusions were considered to be appropriate (pretransfusion fibrinogen level <or=1 g/L in 19% and posttransfusion fibrinogen level <or=1.0 g/L in another 5%), 34 percent were inappropriate, and in 42 percent appropriateness could not be determined. CONCLUSION: A 2-month audit of cryoprecipitate use in Canada revealed that the majority of cryoprecipitate use in Canada is not in accordance with published guidelines.
11
Practice Guidelines for Blood Component Therapy
Anesthesiology · 1996 · 759 citations
Medicine, Hematology, Hemostasis +13
Guidelines on the management of massive blood loss
D. Stainsby, Sheila MacLennan, Dafydd G. Thomas et al. · British Journal of Haematology · 2006 · 391 citations
Medicine, Hematology, Obstetrics +17
Practice Parameter for the Use of Fresh-Frozen Plasma, Cryoprecipitate, and Platelets
E. Shannon Cooper · JAMA · 1994 · 297 citations
Medicine, Hematology, Pediatrics +17