Journal of Thoracic Imaging · 1997 · 32 citations · 0 references
MedicineOncologyRadiologyCancer ScreeningDiagnostic ImagingDiagnostic RadiologyCancer DetectionChest RadiographyChest RadiologyComputed TomographyLung CancerThoracic RadiographyChest Radiography FindingsChest Radiography ScreeningHelical Computed TomographyLung Cancer ScreeningLung Cancer StagingMedical Imaging ScreeningScreening Chest RadiographyThoracic Malignancy Detection
We evaluated the usefulness of low-dose helical computed tomography (CT) as a routine second step in patients screened for lung cancer with plain chest radiography (PCR). Of 5,437 people who underwent mass screening for lung cancer by PCR, further work-up was required for 230 because of abnormal findings. Of 221 subjects who had CT as a second step, abnormal shadows were detected in 110 and no abnormal shadows were seen in 111. Screening CT (helical scan; beam collination, 10 mm; pitch of 2:20 mm/s; and tube current, 50 mA) detected 17 lung cancers, 87 benign lesions, and 6 extrapulmonary lesions, with an average diameter of 10 mm (range, 2-35 mm). All lung cancers were peripheral (12 stage I, 4 stage IIIA, and 1 stage IV). In 40% of screened subjects, 37 with benign lesions and 7 with lung cancer (6 stage I), lesions were delineated only by screening CT. In conclusion, low-dose helical CT was found to be useful as a second step in patients who have been screened for lung cancer by PCR and can delineate the early stage of lung cancer.