The Journal of Urology · 2007 · 89 citations · 18 references
MedicinePharmacotherapyUrologyNeurourologyUrodynamicsVoiding DysfunctionBladder Function AssessmentErectile DysfunctionMale UrodynamicsMale Voiding DysfunctionUrinary IncontinenceUrodynamic EvaluationDetrusor Overactivity ManagementDetrusor Pressure AssessmentDetrusor Pressure MeasurementSpinal Cord Injury-related Bladder DysfunctionSpinal Cord Injury-related Voiding DysfunctionUrodynamic AbnormalitiesUrodynamic Data InterpretationUrodynamic Pressure Measurement
PURPOSE: We assessed urodynamic changes after vardenafil administration in spinal cord injured male patients on oxybutynin treatment. MATERIALS AND METHODS: We performed a single center, randomized, double-blind, placebo controlled trial in 25 patients with spinal cord injury who had erectile dysfunction and micturition disorders. A baseline urodynamic test was performed as well as a second urodynamic test 1 to 3 hours after the administration of 20 mg vardenafil and placebo in 15 and 10 cases, respectively. In all patients standard oral oxybutynin administration was not discontinued. Statistical assessment included the 3 urodynamic parameters maximum detrusor pressure during voiding, maximum cystometric capacity and detrusor overactivity volume. RESULTS: Placebo administration did not affect urodynamic parameters. After vardenafil administration maximum detrusor pressure was significantly decreased (59.3 vs 52.1 cm H(2)O, p <0.001) and maximum cystometric capacity considerably improved (233.5 vs 272 ml, p <0.001). The most dramatic variations were observed for detrusor overactivity volume (174 vs 218 ml, p <0.0001). In 7 patients with American Spinal Injury Association classification A and spinal cord injury above T6 we observed the most significant improvement in the evaluated urodynamic items, including maximum detrusor pressure 57 vs 52 cm H(2)O (p = 0.039), maximum cystometric capacity 253 vs 296 ml (p = 0.004) and detrusor overactivity volume 177 vs 229 ml (p = 0.003). CONCLUSIONS: This trial demonstrates that in spinal cord injured patients a single 20 mg vardenafil administration achieved a significant decrease in maximum detrusor pressure, an improvement in maximum cystometric capacity and a remarkable increase in detrusor overactivity volume value.
18
Good urodynamic practices: Uroflowmetry, filling cystometry, and pressure‐flow studies**
Werner Schäfer, Paul Abrams, Limin Liao et al. · Neurourology and Urodynamics · 2002 · 1.7K citations · Full text
Medicine, Urology, Female Urology +15
NIH Consensus Conference. Impotence. NIH Consensus Development Panel on Impotence
JAMA · 1993 · 843 citations
Kevin T. McVary, William B. Monnig, Joseph L. Camps et al. · The Journal of Urology · 2007 · 350 citations
Medicine, Pharmacotherapy, Urology +16
Joachim W. Thüroff, Björn Bunke, Arno Ebner et al. · The Journal of Urology · 1991 · 258 citations
Medicine, Pharmacotherapy, Urology +16