Hybridoma · 1992 · 64 citations · 16 references
Life SciencesImmunologyClinical ImmunologyImmunotechnologyMonoclonal AntibodiesAntibody-antigen RecognitionDiagnostic Monoclonal AntibodiesMonoclonal Antibody TherapyDetection AntibodiesFalse-positive ResultsImmunodiagnostic AssaysImmunological AssaysInterferenceMonoclonal Antibody AssaysMonoclonal Antibody-based AssaysSandwich Enzyme-linked Immunosorbent Assay
Human anti-murine antibodies (HAMA) can be found in serum of many patients who have received murine monoclonal antibodies for diagnosis or therapy. These antibodies are known to give false positive results in sandwich-type assays (e.g. ELISA or RIA). This interference problem will increase in the future as more patients are treated with murine monoclonal antibodies in vivo. HAMA can also be found in sera from patients that has not been treated with monoclonal antibodies. In this work we have studied the interference of HAMA in sandwich ELISAs containing antibodies from different species. HAMA, present in the sample, may react both with the capture antibody and the detection antibody in these assays to give a false positive reaction. HAMA did not react with chicken IgG, and if one of (or both) the capture and detection antibody was of avian origin, the interference of HAMA in sandwich assays could be avoided.
16
Heterophilic antibodies: a problem for all immunoassays.
L M Boscato, Marc C. A. Stuart · Clinical Chemistry · 1988 · 301 citations · Full text
The Chicken Egg, an Antibody Source
U. Lösch, I. Schranner, Rüdiger Wanke et al. · Journal of Veterinary Medicine Series B · 1986 · 135 citations