DIFFUSIVITY DETERMINATION FROM THE RESPONSE TO INJECTION INTO LAMINAR LIQUID FLOW IN A CAPILLARY

V. Hančil, Vladimír Rod, Miriam A. Rosenbaum

Chemical Engineering Communications · 1979 · 17 citations · 6 references

Concepts

Abstract

A method for the determination of diffusivities in liquids is described; the method is based on measurements of the response to injection in a laminar flow of liquid in a capillary. By injection of δ-type, the component whose diffusivity is to be measured is introduced into the inlet part of a capillary of internal diameter 1.6 mm. The response to the injection is measured at the end of the capillary by a flow-through refractometer, the output signal of which is recorded on tape at 16-s intervals. The output signal is compared with a theroetical model of the time dependence of the response, based on Taylor's analysis of the dispersion of an injected component in laminar flow. The diffusivity is calculated from one of the model parameters, which were evaluated by the method of maximum likelihood. The calibration of the instrument was performed by measuring the diffusivity of KC1 in aqueous solution. The following diffusivities at 25°C were determined: n-butanol 971 μm2/s, dioxane 1093μm2/s, caprolactame 948 μm2/s, Na2SO4, 1126 μm2/s, salicylaldoxime 895 μm2/s, cyclohexanone 960 μm2/s, acetone 1316μm2/s, oxine 820.5 μm2/s, all in water; caprolactame in trichlorethylene 1958μm2/s, caprolactame in 10% aqueous (NH44)2,SO4 solution 1148 μm2/s, salicylaldoxime in chloroform 1878 μm2/S.