Clinical Oral Implants Research · 2007 · 95 citations · 92 references
MedicinePeriodonticsSurgeryBone AugmentationBone GraftingTissue EngineeringBarrier MembranesBone Defect ReconstructionBone Graft SubstitutesBone Loss ReconstructionBone ReconstructionBone Tissue EngineeringAcellular Dermal Matrix GraftAcellular Dermal Matrix MembranesAcellular Dermal Matrix UseBone Defect RepairCollagen Membrane CoveringCollagen-based Barrier MembranesHorizontal Bone AugmentationHorizontal Bone Defects
OBJECTIVES: This study was conducted to evaluate the effect of barrier membranes on sandwich bone augmentation (SBA) for the treatment of implant dehiscence defects. MATERIAL AND METHODS: Twenty-six implant-associated buccal dehiscence defects in 22 patients were treated according to the SBA concept - mineralized human cancellous allograft (inner layer), mineralized human cortical allograft (outer layer) and coverage with barrier membrane. The defects were randomly assigned to the bovine collagen membrane (BME) group; acellular dermal matrix (ADM) group; and no membrane group. Measurements at baseline and 6 months re-entry included defect height (DH: from smooth-rough junction to the most apical part of the defect), defect width (DW: at the widest part of the defect), and horizontal defect depth (HDD: at three locations - smooth-rough junction, middle, and most apical portion of the defect). All measurements were taken from a reference stent. Statistical analyses were performed for comparison of intra- and inter-group comparisons. RESULTS: All implants placed were successfully osseointegrated. DH at baseline for three groups were not significantly different (P=0.858). Mean % DH reductions for ADM, BME, and control groups at 6 months were 73.9+/-17.6%, 68.1+/-30.1%, and 63.6+/-23.9%, respectively, with no significant difference among the groups (P=0.686). Mean horizontal bone gain, however, was significantly greater for membrane groups (1.7 mm for ADM, 1.6 mm for BME) compared with control group (1 mm) (P=0.044). Implant exposure resulted in significant reduction in total height gain (79.1+/-14.3% vs. 57+/-23.5%, P=0.021). CONCLUSIONS: Within the limit of this study, it is concluded that SBA technique achieved predictable clinical outcomes. The addition of absorbable membranes enhanced bone gain in thickness compared with membrane-treated sites.
92
Bone graft materials. An overview of the basic science.
Thomas W. Bauer, George F. Muschler · PubMed · 2000 · 1.1K citations
Thomas W. Bauer, George F. Muschler · Clinical Orthopaedics and Related Research · 2000 · 988 citations
Shuichiro Shiina, Hiromu Aoyama, Yasushi Shiratori et al. · Investigative Radiology · 1990 · 655 citations
Veterinary Medicine, Veterinary Pathology, Veterinary Pharmacology +13