IEEE Transactions on Industry Applications · 2013 · 53 citations · 17 references
EngineeringElectrical EngineeringElectric MachinesMicroelectronicsPower ElectronicsConverter TopologiesDc-ac InvertersElectric Motor Drive SystemsElectric Motor DrivesElectric Traction MotorsSoft-switching TechniquesLoss AnalysisPower OutputSoft SwitchingSoft-switching Converter TopologiesSoft-switching ConvertersSoft-switching InvertersSwitch ArchitectureZero-voltage Switching
This paper presents a hybrid switch that parallels a power MOSFET and an insulated-gate bipolar transistor (IGBT) as the main switch of a zero-voltage switching (ZVS) inverter. The combination features the MOSFET conducting in the low-current region and the IGBT conducting in the high-current region, and the soft switching avoids the reverse recovery problem during the device turn-on. A custom hybrid switch module has been developed for a variable-timing-controlled coupled-magnetic-type ZVS inverter with a nominal input voltage of 325 V and the continuous output power of 30 kW for a traction motor drive. Experimental results of the hybrid-switch-based inverter with the total loss projected by temperature indicate that the inverter achieves 99% efficiency at the nominal condition and demonstrate ultrahigh-efficiency operation over a wide load range. At 375-V input, the maximum measured efficiency through temperature projection and loss separation analysis is 99.3%.
17
The auxiliary resonant commutated pole converter
Rik W. De Doncker, J.P. Lyons · 2002 · 662 citations
A delta configured auxiliary resonant snubber inverter
Jih‐Sheng Lai, R. W. Young, G.W. Ott et al. · 2002 · 128 citations · Full text
Engineering, Electrical Engineering, Marine Electrical Systems +14