Physical Review E · 2011 · 21 citations · 32 references
Natural SciencesBiophysicsPhysicsBiomechanicsFluid DynamicsRheologyBiofluid MechanicsBlood RheologyBlood ViscosityHemodynamicsRed Blood Cell PhysiologyViscous FlowBlood Flow DynamicsBlood Flow Under ShearCapillary NumberCell ViscosityOscillatory FlowRed Blood Cell DynamicsShear FlowsViscosity
In this paper, we investigate the oscillatory dynamics of the tank-treading motion of healthy human erythrocytes in shear flows with capillary number Ca = O(1) and small to moderate viscosity ratios 0.01 ≤ λ ≤ 1.5. These conditions correspond to a wide range of surrounding medium viscosities (4-600 m Pa s) and shear flow rates (2-560 s(-1)), and match those used in ektacytometry systems. For a given viscosity ratio, as the flow rate increases, the steady-state erythrocyte length L (in the shear plane) increases logarithmically while its depth W (normal to the shear plane) decreases logarithmically. In addition, the flow rate increase dampens the oscillatory erythrocyte inclination but not its length oscillations (which show relative variations of about 5-8%). For a given flow rate, as the viscosity ratio increases, the erythrocyte length L contracts while its depth W increases (i.e., the cell becomes less deformed) with a small decrease in the length variations. The average orientation angle of the erythrocyte shows a significant decrease with the viscosity ratio as does the angle oscillation while the oscillation period increases. These trends continue in higher viscosity ratios resulting eventually in the transition from a (weakly oscillatory) tank-treading motion to a tumbling motion. Our computations show that the erythrocyte width S, which exists in the shear plane, is practically invariant in time, capillary number, and viscosity ratio, and corresponds to a real cell thickness of about 2.5 μm. Comparison of our computational results with the predictions of (low degree-of-freedom) theoretical models and experimental findings, suggests that the energy dissipation due to the shape-memory effects is more significant than the energy dissipation due to the membrane viscosity. Our work shows that the oscillatory tank-treading motion can account for more than 50% of the variations found in ektacytometry systems; thus, researchers who wish to study inherent differences between erythrocytes within a population must devise a way of monitoring individual cells over time so that they can remove the oscillation effects.
32
Strain Energy Function of Red Blood Cell Membranes
Richard Skalak, Aydın Tözeren, R.P. Zarda et al. · Biophysical Journal · 1973 · 827 citations · Full text
MICROCIRCULATION AND HEMORHEOLOGY
Aleksander S. Popel, Paul C. Johnson · Annual Review of Fluid Mechanics · 2005 · 813 citations · Full text
Improved measurements of the erythrocyte geometry
Evan Evans, Y. C. Fung · Microvascular Research · 1972 · 585 citations