Heart · 1984 · 16 citations · 5 references
MedicineCardiologySurgeryBiomedical ImagingCardiothoracic SurgeryClinical CardiologyCardiovascular ImagingComputed TomographyCoronary AngiographyCoronary Artery ImagingCoronary Artery SurgeryBypass Graft Patency AssessmentCardiac Computed TomographyComputed Tomography Coronary AssessmentCoronary Ct AngiographyCoronary Flow AssessmentImaging-based Graft AssessmentIntraoperative Graft Patency AssessmentTomographic Imaging
Twenty four patients with 65 coronary artery bypass grafts were studied by computed tomography and angiogrphy within a 10 day period in order to assess graft patency and graft flow. In the assessment of graft patency computed tomography had an accuracy of 93% and in that of graft flow one of 91%. These results indicate that computed tomography is an accurate method for assessing graft patency and flow and is useful in the investigation of certain groups of patients who have had coronary artery bypass graft surgery.
5
Detection of patent coronary bypass grafts by computed tomography. A preliminary report.
Bruce H. Brundage, Martin J. Lipton, R J Herfkens et al. · Circulation · 1980 · 122 citations
Value and limitations of computed tomography in assessing aortocoronary bypass graft patency.
W.G. Daniel, W. Döhring, H. St. Stender et al. · Circulation · 1983 · 70 citations · Full text
Clinical value of coronary bypass graft evaluation with CT
J. David Godwin, RM Califf, Melvyn Korobkin et al. · American Journal of Roentgenology · 1983 · 27 citations
Medicine, Cardiology, Surgery +17