Critical Care Medicine · 2014 · 176 citations · 39 references
MedicineCardiologySurgeryCardiothoracic SurgeryCritical Care CardiologyHemodynamic ManagementCardiogenic ShockExtracorporeal Life SupportExtracorporeal Membrane OxygenationHemodynamic SupportMicrocirculatory DysfunctionMicrocirculatory PerfusionHemodynamic MonitoringIntra-aortic Balloon PumpingMicrocirculationMicrocirculatory Perfusion AssessmentPulmonary Artery Occlusion PressureShock-related Microcirculatory DysfunctionTissue Oxygenation MeasurementTissue Oxygenation Monitoring
OBJECTIVES: This study was designed to assess the effects on macrocirculation and microcirculation of adding an intra-aortic balloon pump to peripheral venoarterial extracorporeal membrane oxygenation in patients with severe cardiogenic shock and little/no residual left ventricular ejection. DESIGN: A prospective, single-center, observational study where macrocirculation and microcirculation were assessed with clinical-, Doppler echocardiography-, and pulmonary artery-derived hemodynamic variables and also cerebral and thenar eminence tissue oxygenation and side-stream dark-field imaging of sublingual microcirculation. SETTING: A 26-bed tertiary ICU in a university hospital. PATIENTS: We evaluated 12 consecutive patients before and 30 minutes after interrupting and restarting intra-aortic balloon pump. INTERVENTIONS: Measurements were performed before, and 30 minutes after interrupting and restarting intra-aortic balloon pump. MEASUREMENTS AND MAIN RESULTS: Stopping intra-aortic balloon pump was associated with higher pulmonary artery-occlusion pressure (19 ± 10 vs 15 ± 8 mm Hg, p = 0.01), increased left ventricular end-systolic (51 ± 13 vs 50 ± 14 mm, p = 0.05) and end-diastolic (55 ± 13 vs 52 ± 14 mm, p = 0.003) dimensions, and decreased pulse pressure (15 ± 13 vs 29 ± 22 mm Hg, p = 0.02). Maximum pulmonary artery-occlusion pressure reduction when the intra-aortic balloon pump was restarted was observed in the seven patients whose pulmonary artery-occlusion pressure was more than 15 mm Hg when intra-aortic balloon pump was off (-6.6 ± 4.3 vs -0.6 ± 3.4 mm Hg, respectively). Thenar eminence and brain tissue oxygenation and side-stream dark-field-assessed sublingual microcirculation were unchanged by stopping and restarting intra-aortic balloon pump. CONCLUSIONS: Restoring pulsatility and decreasing left ventricular afterload with intra-aortic balloon pump was associated with smaller left ventricular dimensions and lower pulmonary artery pressures but did not affect microcirculation variables in cardiogenic shock patients with little/no residual left ventricular ejection while on peripheral venoarterial extracorporeal membrane oxygenation.
39
Sherif F. Nagueh, Katherine J. Middleton, Helen A. Kopelen et al. · Journal of the American College of Cardiology · 1997 · 3K citations
Intraaortic Balloon Support for Myocardial Infarction with Cardiogenic Shock
Hölger Thiele, Uwe Zeymer, Franz–Josef Neumann et al. · New England Journal of Medicine · 2012 · 2.8K citations · Full text